WLS-35 outdoor three-core
Project-focused selection
Quality-controlled supply
Export service
WLS-35 Outdoor Three-Core Cable Termination overview
The WLS-35 Outdoor Three-Core Cable Termination is listed in the GRL range for cable termination and joint selection. Use the model-specific information below to compare voltage class and cable core arrangement, conductor size and cable insulation diameter and indoor or outdoor installation and accessory scope before selecting a configuration.

Ordering Information
| Product Name | Voltage level | Product Specifications | Product Model | Cable cross-sectional area | Main insulation outer diameter of the cable (m) | Set/Weight (kg) |
| Three-core outdoor terminal | 26/35kV | 3.1# | WLS35-3×1 | 50~95 | 86~94 | 8.46 |
| 26/35kV | 3.2# | WLS35-3×2 | 120~185 | 98~105 | 8.48 | |
| 26/35kV | 3.3# | WLS35-3×3 | 240~400 | 111~124 | 8.59 | |
| 26/35kV | 3.4# | WLS35-3×4 | 500~630 | – | 9.05 | |
| 26/35kV | 3.5# | WLS35-3×5 | 700 | – | 9.2 | |
| 26/35kV | 3.6# | WLS35-3×6 | 800 | – | 9.3 |
Standard accessories package
| Product Specifications | Tape measure | Sandpaper strips | Band-aid | Cleaning paper | triangular pyramid | Silicone grease | Filling glue | Sealant | Shielded ground wire | Armored ground wire |
| Roll | Strip | Open | Bag | indivual | Strip | Bag | Bag | Strip | Strip | |
| 1#(50-95mm²) | 1 | 2 | 2 | 3 | 1 | 2 | 3 | 3 | 1 | 1 |
| 2#(120-185mm²) | 1 | 2 | 2 | 3 | 1 | 2 | 3 | 3 | 1 | 1 |
| 3#(240-400mm²) | 1 | 2 | 2 | 4 | 1 | 2 | 3 | 3 | 1 | 1 |
| 4#(500-630mm²) | 1 | 2 | 2 | 4 | 1 | 2 | 3 | 3 | 1 | 1 |
| 5#(700mm²) | 1 | 2 | 2 | 5 | 1 | 2 | 3 | 3 | 1 | 1 |
| 6#(800mm²) | 1 | 2 | 2 | 5 | 1 | 2 | 3 | 3 | 1 | 1 |
| Product Specifications | Auxiliary gloves | work gloves | disposable gloves | Constant force spring | PVC electrical tape | J-30 type self-adhesive rubber tape | BDD-50 Semiconducting Self-Adhesive Tape | Certificate of Conformity | Fixed-length calipers | Installation process book | |
| Specification | quantity | ||||||||||
| pair | pair | pair | indivual | indivual | box | box | open | open | open | ||
| 1#(50-95mm²) | 1 | 1 | 2 | 32 | 2 | 3 | 1 | 1 | 1 | 1 | 1 |
| 2#(120-185mm²) | 1 | 1 | 2 | 36 | 2 | 3 | 1 | 1 | 1 | 1 | 1 |
| 3#(240-400mm²) | 1 | 1 | 2 | 40 | 2 | 3 | 1 | 1 | 1 | 1 | 1 |
| 4#(500-630mm²) | 1 | 1 | 2 | 45 | 2 | 3 | 1 | 1 | 1 | 1 | 1 |
| 5#(700mm²) | 1 | 1 | 2 | 55 | 2 | 3 | 2 | 2 | 1 | 1 | 1 |
| 6#(800mm²) | 1 | 1 | 2 | 60 | 2 | 3 | 2 | 2 | 1 | 1 | 1 |
Selecting WLS-35 Outdoor Three-Core Cable Termination
Before requesting a quotation, confirm voltage class and cable core arrangement, conductor size and cable insulation diameter and indoor or outdoor installation and accessory scope. Send the exact model, quantity and installation details so the configuration and document set can be checked against your project.
Compare the cold shrink bushing range, including WLS-10-1.1-1.4; WLS outdoor single core. For drawings and order-specific questions, send your product requirements to GRL.







