Overview

The ZW32-12F outdoor AC high-voltage vacuum demarcation circuit breaker (hereinafter referred to as the demarcation circuit breaker) is a multifunctional intelligent device that integrates a vacuum circuit breaker, a demarcation circuit breaker, and a sectionalizer. It primarily consists of the vacuum demarcation circuit breaker, an intelligent demarcation controller, and an external voltage transformer (Note: dual-side PTs are optional in distribution network automation ring lines). This product is widely used in 10kV urban and rural overhead ring lines as a sectionalizing disconnector, tie switch, and automated switchgear for load distribution in ring lines. It can also serve as a demarcation switch (commonly known as a watchdog) in branch lines supplying large users and as a demarcation circuit breaker and sectionalizer in feeder overhead distribution networks. The vacuum demarcation circuit breaker features remote management, protection control, and communication capabilities. It can reliably detect milliampere-level zero-sequence currents and phase-to-phase short-circuit fault currents within the demarcation boundary, automatically clearing single-phase grounding faults and phase-to-phase short-circuit faults.

This product manual covers the reference standards, operating environment conditions, models and rated parameters, structural features, working principles, ordering instructions, and methods of operation, installation, use and maintenance of the boundary circuit breaker.

Model meaning

ZW32-12F Outdoor AC High Voltage Vacuum Boundary Circuit Breaker

Main technical parameters

Project Unit Parameter
Rated voltage kV 10
Maximum operating voltage kV 12
Rated insulation level 1min power frequency withstand voltage Dry test kV 42
Rated insulation level 1min power frequency withstand voltage Wet test kV 34
Rated insulation level Lightning impulse withstand voltage kV 75
Rated current A 630
Rated short-circuit breaking current kA 20
Rated capacitor bank breaking current A 400/630
Rated operating sequence 0-0.3S-CO-15S-CO-15S-CO
Rated short-circuit breaking current breaking times times 20
Rated short-circuit making current (peak value) kA 50
Rated peak withstand current kA 50
Rated short-time withstand current kA 20
Rated short-circuit duration s 4
Full break time ms ≤100
Trip time (shunt trip) Maximum operating voltage ms 15~50
Trip time (shunt trip) Rated operating voltage ms 15~50
Trip time (shunt trip) Minimum operating voltage ms 30~60
Closing time ms 25~60
Mechanical life times 10000
Rated operating voltage V AC220
Operating mechanism CT37-D spring mechanism
Allowable wear thickness of moving contact mm 3
Weight kg 110 (135 with disconnector)
Energy storage motor rated input power W ≤250
Overcurrent release Rated current A 5
Overcurrent release Tripping accuracy % ±10

Appearance and installation dimensions (mm)

ZW32-12F Outdoor AC High Voltage Vacuum Boundary Circuit Breaker

Schematic diagram of single-pole installation of boundary circuit breaker

ZW32-12F Outdoor AC High Voltage Vacuum Boundary Circuit Breaker

Project inquiry

Tell Us What Your Project Needs

Include the voltage level, quantity, application and destination market for a faster response.
询盘表单