Get a Quote
Home / Products / Indoor High-Voltage / High Voltage Circuit Breaker / Vacuum Circuit Breakers / ZW7-40.5 outdoor high voltage vacuum circuit breaker
Vacuum Circuit Breakers

ZW7-40.5 outdoor high voltage vacuum circuit breaker

ZW7-40.5 outdoor high-voltage vacuum circuit breaker is used in three-phase power systems with AC 50H2 and rated voltage of 40.5kV to disconnect and close load current, overload current and short-circuit current.

Project-focused selection

Support matched to operating conditions and project requirements.

Quality-controlled supply

Clear communication from confirmation through delivery.

Export service

Documentation and shipping support for overseas buyers.

Overview

ZW7-40.5 outdoor high-voltage vacuum circuit breaker is used in three-phase power systems with AC 50H2 and rated voltage of 40.5kV to disconnect and close load current, overload current and short-circuit current.

Model meaning

ZW7-40.5 outdoor high voltage vacuum circuit breaker 

Main functions

Adopting vacuum arc extinguishing, strong breaking capacity, long electrical life and mechanical life of 10,000 times;

Simple structure, maintenance-free, and long maintenance cycle;

Good insulation performance and strong anti-fouling ability;

Can be equipped with spring or electromagnetic operating mechanism, with reliable mechanical performance and can be operated frequently;

No fire and explosion hazards;

Built-in current transformer with calculation accuracy up to 0.2 level, which can realize three-phase dynamic protection;

The built-in condensation controller can keep the circuit breaker running reliably under certain temperature and humidity.

Operating environment conditions

Air temperature: upper limit +40℃, lower limit -30℃;

Altitude: ≤2000m (if the altitude needs to be increased, the rated insulation level will be increased accordingly);

Wind pressure: no more than 700Pa (equivalent to wind speed 34m/s);

Earthquake intensity: 8 degrees;

Pollution level: Level III;

Maximum daily temperature difference: no more than 25℃

Main technical parameters

Project Unit Parameter
Rated voltage kV 40.5
Rated insulation level Power frequency withstand voltage Dry kV 95
Wet kV 80
Lightning impulse withstand voltage (peak) kV 185
Rated current A 1250、1600、2000
Rated short-circuit breaking current kA 20、25、31.5
Rated operating sequence 分-0.3S合分-180S合分
Rated short-circuit current breaking times 次 12
Rated short-circuit closing current (peak value) kA 50、63、80
Rated peak withstand current kA 50、63、80
Rated short-time withstand current kA 20、25、31.5
Rated short-circuit continuous current S 4
Average opening speed m/s 1.5±0.2
Average closing speed m/s 0.7±0.2
Contact closing bounce time S ≤2
Three-phase closing (opening) synchronism time difference S ≤2
Closing time S ≤150
Opening time S ≤60
Mechanical life 次 10000
Rated operating voltage and auxiliary circuit rated voltage V DC220、110、24
Rated operating voltage and auxiliary circuit rated voltage V AC220、110、24
Rated operating voltage and auxiliary circuit rated voltage μΩ ≤100
Allowable wear thickness of moving and static contacts mm 3
Weight kg 800